Ziton Software Planner Login

Ziton Radio Loop Module Programming Manual (Issue 7d) TSD022. Software Version Loop Address Output Test** Fault Status Background Level Ident Software Version.

• Security ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual. • Trademarks and patents GE and the GE monogram are trademarks of General Electric Company. The ZP3 Fire Control Panel name and logo are trademarks of GE Security. • ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Table of contents Heading Page List of abbreviations and acronyms..x Associated publications and references.. X General warnings and precautions..xi Primary supply...xi Back-up battery supply..xii Regulatory information..xii Chapter 1: Installation overview..1.

• ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Good connections..43 Careful handling of electronics..43 Cleanliness...43 Neatness... 43 Chapter 3: Field wiring..45 Terminal layout...45 Power supply... 46 Mains supply...46 Auxiliary 24 VDC supply..47 External power for accessory boards..

• ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual System configuration: relays.. 75 System configuration: printer..

75 System configuration: [various]..76 Planner...77 Level 4 operations..77 Chapter 5: System configuration.. 79 System specification..79 General information..79 Input-output mapping.. Tumhe dillagi bhool jani padegi qawwali mp3 nusrat fateh ali khan.

• ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual New data structure... 95 Compatibility with Maestro and Planner..95 Peer-to-peer 3 (P2P3) protocol..95 Overview...95 Compatibility with older versions of panel software.95 P2P3 New features..96 Panel comms enable/disable.. 96 Inter-panel support for remote diagnostics across the network. • Figure 4: ZP3 Fire control panel - modular construction..9 Figure 5: ZP3 Fire control panel – internal features..10 Figure 6: ZP3 Fire control panel – main chassis assembly.. 11 Figure 7: ZP3 Fire Control Panel - Door Assembly..13 Figure 8: ZP3 Fire control panel –. • ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Figure 18: ZP3 Fire control panel – accessory plate..24 Figure 19: Mounting auxiliary boards..25 Figure 20: ZP3AB-MD3 Modem..26 Figure 21: Installing the modem mounting bracket..27 Figure 22: Installing the modem..

• Table 27: Loop length cable size (various diameters) – assuming no high power devices.109 Table 28: DC Cable Size..110 Table 29: ZP3 fire control panel – quarterly checks..111 Table 30: ZP3 fire control panel – annual checks..113 Table 31: Keypad description..114 Table 32: Device definition table and device type analogues interpretation.122 Table 33: Analogue status –. • ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual List of abbreviations and acronyms Table 1 lists and defines the abbreviations and acronyms used in this manual. Table 1: Abbreviations and acronyms Abbreviation Definition Direct Current Ground Liquid Crystal Display.

• Panel, and has been prepared in accordance with ZP3 operating software version 3.11. General warnings and precautions Trained service personnel must carry out procedures in this manual. The ZP3 panel is powered from a 230 VAC primary supply and from a 24 VDC battery backup supply. Primary supply WARNING: THE POWER SUPPLY FORMS PART OF THE MAIN BOARD ASSEMBLY. • Certification Certification body 1134 Certificate number 1134-CPD-089 Manufacturer GE Security Africa, 555 Voortrekkerroad, Maitland, Cape Town 7405, PO Box 181 Maitland, South Africa Manufacturer’s GE Security B.V., Kelvinstraat 7, 6003 DH Weert, The Netherlands representative (Europe) Page xii REV 11 (ISS ) • Chapter 1: Installation overview Introduction The ZP3 fire control panel (see Figure 1) is a state-of-the-art analogue addressable panel that complies with the EN54 parts 2 and 4 standards.

It is a compact microprocessor controlled unit, of modular design. Hardware and software modules enable you to configure virtually any system requirement.

• ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Specification Refer to Table 4 for a detailed specification of the ZP3 Fire Control Panel. Table 4: ZP3 Fire control panel specification Description Specification/ Remarks parameters Specification Compliance Fire alarm panel. • ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Description Specification/ Remarks parameters Output Current Total continuous 2.6 A at 21 VDC See note 2 Total continuous 3.0 A at 24 VDC See note 2 Total peak 5.5 A at 24 VDC. • ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Description Specification/ Remarks parameters Power supply (external) Primary supply 24 to 28 VDC, Optional - Supplied from an external charger (Amps dependant on system load) Output (mains OFF) 24 VDC 15 to 27.6 VDC depending upon state of battery. • ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Description Specification/ Remarks parameters Control buttons/keys Help Button Displays operator instructions on-screen View fire alarm Button Displays “Fire Alarms by Zone” screen View fault alarm Button Displays “Fault Alarms by Zone” screen. • ZP3 Fire Control Panel Installation, Commissioning and Maintenance Manual Description Specification/ Remarks parameters Zone pre-alarm Yellow Point pre-alarm Yellow System test mode Yellow Power on Green Switched outputs (standard) Sounder circuits Monitored sounder circuits, programmable as one o/p (Common/programmable) “1 + 2”.

Related Post